Disassembly is fairly modest, but the IC repair is elaborate. The good news that the IC itself is cheap and readily available from Mouser, DigiKey and other standard suppliers. The typical symptom is that scanner passes power-up initialization fine no fast blinking , but is not recognized by a computer in Windows - Device Manager does not see it.

The scan software reports that it cannot find a scanner. But replacing it did not fix the problem Disassembly and repair are fairly modest. There are two different typical symptoms:.

Even when the motor is replaced - the scanner still fails to operate it properly. When you insert SF into the scanner - the power light blinks few times but no motor sounds occur. The scanner reports failure to load film. Scanner does not work with SA When SA is inserted it makes a loud grinding noise, see here:. Most frequently, the scanner may show one of the following problems:. See this video. If you power up the scanner with the adapter inserted, the scanner main stepper motor will make a loud high pitched whirring sound at the end of startup, see here.

Sometimes the scanner will blink fast after the loud whirring sound, sometimes not. Both of this are indicative of the main stepper motor failure.

The replacement procedure is fairly straightforward, the problem is a replacement motor. I could not find a suitable motor, so I have to scavenge older cheaper models for these. This is a fairly common failure of LS and LS's. The scan head is moved by a worm gear. The worm shaft is held in place by a steel plate on one side and by a plastic part from another side. That plastic part may break if the scanner was not handled gently during shipping etc.

Significant disassembly is required - follow the steps of Nikon disassembly procedure or Nikon disassembly procedure all the way to the end. Again, just buy a working LS on e-bay for spare parts. Unfortunately, sometimes the little gear that ties the scan-head to the worm drive breaks.

Replacing it is no more difficult than replacing the small support part above. This issue was brought to my attention by Frank Phillips. First this shows both FireWire card and Scanner installed and working in device manager First one is color negative So yes, these scanners work under Windows Tutorial updated.

Peace: -- hide signature Reply Reply with quote Reply to thread Complain. Nikon Coolscan works under Windows 10!!! Re: Nikon Coolscan works under Windows 10!!! Forum Parent First Previous Next. Color scheme? Latest sample galleries. Canon EOS R3 sample gallery. Nikon Z9 production sample gallery. See more galleries ». Latest in-depth reviews. Read more reviews ». Latest buying guides. Best cameras for landscape photography in Best drones in Best video cameras for photographers in Best cameras for Instagram in Check out more buying guides ».

Leica M Click the button in the thumbnail drawer to hide thumbnails, and then select the correct film type from the film type menu. Click the button to view the new thumbnails. Preview button If multiple frames are selected, additional frames can be previewed by clicking the thumbnails in the thumbnail drawer. The borders of the crop are indicated by a dotted line. The size of the crop can be changed by dragging its borders.

To change the position of the crop, place the cursor inside the selected area and drag it to a new location. Click to display Layout Tools palette Crop Tool Repeat this step for the other images selected in the thumbnail drawer.

To display images in the preview area, open the thumbnail drawer and click the selected thumbnails. For example, to scan an image so that it can be printed within the margins of A4 The other value will automatically be adjusted to maintain the current crop; if the result is still too large, enter a value that will fit on A4 paper.

Scan Image Enhancer The image enhancement tools in the Tool Chest can be used to enhance images before they are scanned. Progress is shown in the progress window Batch Scans If multiple frames are selected in the 32 , clicking the thumbnail drawer Scan button will display a dialog of batch scan options. Click OK to save the scanned images to disk. Scan button The MA can not be used to perform batch scans.

When scanning is complete, images will be opened in image windows in the host application single scans only. Click the Save button to save the image to disk. Repeat steps 2 and 3 until all images have been saved. See the Nikon Scan Reference Manual for more information. Ejection is complete when the status LED has stopped blinking. Wait until ejection is complete before removing film by hand. Pulling on the film during ejection could damage the film or cause errors.

If the scan window was closed before the film was ejected, turn the scanner off and then on again. The film will be ejected automatically. MA Confirm that the status LED is not blinking and press the eject button on the front of the adapter to eject the slide. Scanner on Scanner off The SA Lock Mechanism If the scanner is turned off with film still in place, the adapter lock mechanism 29 will prevent the SA from being removed.

Before attempting to remove the SA, turn the scanner on and wait for the film to be ejected automatically. Attempting to remove the adapter without first ejecting the film could interfere with the connection between the adapter and the scanner. Remove Film Holders When using the optional FH-3 film holder 38 50 , remove the holder before turning the scanner off. Page 48 Nikon Scan This chapter provides a brief overview of the Nikon Scan software that controls the scanner.

In the case of the optional SF slide-feeder adapter for the ED, clicking this button ejects the current slide and feeds a new one. This button can not be used to eject slides from the MA Control-click Windows or option-click Macintosh to select a new focus point. Click to zoom out. A separate Kodachrome option is available for scanning Kodachrome positives.

The values for the Natural panel are listed in the top row, the values for the Processed panel in the bottom row. The Preview and Scan Buttons Preview button Click to preview the image to be scanned if multiple frames are selected in the thumbnail drawer, a preview will be performed for each frame. Be sure to click this button after changing the film type or choosing a new value for analog gain.

If multiple frames are selected, the selected images can be scanned in a single batch. The current task acquiring thumbnails, preview, or scanning is shown at the top of the window. To stop the current task, click Stop. Use the Zoom and Grab tools to navigate images that have been opened in Nikon Scan after scanning.

View the width and height of the current selection and the coordinates of its top left corner. The color value display shows the color of the pixel under the cursor before and after processing. Keep this Crop User selects exact area to be scanned, then selects output size and resolution according to how image will be used.

Best choice in most situations. Keep this Output Size User selects general area to be scanned, then enters exact output size in output size area. Choose this option when image must fit in space of known dimensions. Keep this File Size User selects general area to be scanned, then enters exact file size for final image in file size area.

Choose when file size is paramount, for example when scanning images for electronic distribution. If Keep this Crop is selected, the remaining dimension will automatically be adjusted to maintain the current crop. If Keep this File Size is selected, the remaining dimension and the resolution will automatically be adjusted to maintain the selected file size, and the crop in the preview area will be adjusted accordingly.

Make adjustments to brightness, contrast, and color targeted to specific portions of the tone range for example, this tool can be used to increase brightness in shadows. Make adjustments to brightness and contrast targeted to specific portions of the tone range, or use the hue and chroma editors for precise control of color. Control features specific to the type of scanner currently connected. The FH-3 can be used to scan film that can not be scanned in the SA, either because it is only one frame long or because it has excessive curl or damaged perforations Placing Film in the Holder 1 Open the holder Holding the FH-3 with the Nikon logo uppermost, unlatch the holder snaps and open the holder.

Nikon logo Snap 2 Place film in the holder Place a strip of mm film base up matte emulsion surface down in the bottom half of holder. Align the frame to be scanned with an aperture in the bottom half of the holder.

Aperture 3 Close the holder Close the holder and align the ends of the top and bottom halves. Latch the holder cover and snap the top and bottom halves together at both ends.

Snap shut 4 Align the film with an aperture Slide the black plastic holder until the frame to be scanned is aligned with one of the two apertures in the metal cover. Place the film in the holder base up. When the adapter is fully inserted, the status LED will blink while the scanner initializes Wait until the status LED stops blinking. Slide the holder in until it stops.

To scan frames 1—3, insert the left end of the holder into the scanner. To scan frames 4—6, insert the right end of the holder into the scanner. The eject button on the MA can not be used when removing the FH Errors may occur if the FH-3 is in place when the scanner is turned on. If an error occurs, turn the scanner off and then on again after removing the FH Do not store the scanner where it would be subject to sudden temperature changes or condensation.

Accumulation of dust on the optical parts in the vicinity of the adapter slot could result in scanning errors. Should an error occur, remove dust by sending air into the adapter slot with a blower. Do not insert your fingers into the adapter slot. Cleaning Turn the scanner off, unplug the power cable, and place the scanner on a flat, stable surface where it will not be damaged in a fall.

Use a blower or a soft dry cloth to remove dust, a soft cloth lightly dampened with neutral detergent or liquid soap to remove tougher stains. Do not use alcohol or other volatile chemicals. Servicing Nikon scanners are precision devices. We recommend that the scanner and adapters be taken to an authorized Nikon service representative once every one to two years for inspection, and once every three to five years for servicing fees are charged for these services.

Frequent inspection and servicing are particularly recommended in the case of scanners used in commercial applications. Transporting the Scanner Nikon scanners are certified for use in the region or country of sale only. Transport or use outside the region or country of sale is at the risk and responsibility of the user. Do not store the adapter where it would be subject to sudden temperature changes or condensation. Cleaning The SA is equipped with internal rollers for feeding and ejecting film.

If jams are occurring more frequently, clean the interior of the adapter as described below. Failure to observe this precaution could result in damaged film. Release button Front panel 3 Remove the adapter cover 4 Open the roller frame Release the frame lock lever and open the roller frame. Opening the Roller Frame Stop when resistance is felt. Attempting to force the frame open past this point could damage the adapter. Adapter cover Roller frame Frame lock lever Continuing Jams If jams continue to occur frequently after the interior of the adapter has been cleaned, consult a Nikon service representative.

Excessive force or the use of a screwdriver or other rigid object could damage the wheel. Dry the rollers with a dry cotton swab or leave the roller frame open until the rollers dry. Rollers Toothed wheel Roller frame 6 Clean the sensors and feed mechanism Remove dust from the interior of the adapter with a blower. Clean the three sensors and the feed mechanism thoroughly, changing the angle of the blower to reach all parts of the mechanism.

Cleaning Use a blower or a soft dry cloth to remove dust, a soft cloth lightly dampened with neutral detergent or liquid soap to remove tougher stains. For more information on solving the problems listed here, refer to the page numbers in the rightmost column. Wait five nected to computer, seconds and turn the scanner on again. If the problem persists, conor computer off tact a Nikon service representative.

Wait 22, 24 five seconds and turn the scanner on again. If the status LED flickers when the scanner is turned on, a scanner hardware malfunction has occurred.

Contact the original retailer or a Nikon service representative. After waiting five seconds, turn scanner connected the scanner on and restart the computer. Fail20 ure to observe this precaution could result in scanner malfunction. For more information, see the 31—35 Nikon Scan Reference Manual. If the scanner is connected via a USB hub, adapter, or extension cable, disconnect the scanner and reconnect it directly to the computer.

If this does not solve the problem, uninstall all software that uses the USB interface and reinstall Nikon Scan. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:.

Note that simply being in possession of material which has been copied or reproduced by means of a scanner may be punishable by law. The copying or reproduction of paper money, coins, or securities which are circulated in a foreign country is prohibited.

Unless the prior permission of the government has been obtained, the copying or reproduction of unused postage stamps or post cards issued by the government is prohibited. The copying or reproduction of stamps issued by the government and certified documents stipulated by law is prohibited.

The government has issued cautions on copies or reproductions of securities issued by private companies shares, bills, checks, gift certificates, etc. Also, do not copy or reproduce passports issued by the government, licenses issued by public agencies and private groups, ID cards, and tickets, such as passes and meal coupons. The copying or reproduction of copyrighted creative works such as books, music, paintings, woodcut prints, maps, drawings, movies, and photographs is prohibited except when it is done for personal use at home or for similar restricted and non-commercial use.

The SF S , which can hold up to fifty mounts 1. This manual describes the procedures for unpacking, setting up, and connecting the feeder to your scanner. Please read all instructions thoroughly to ensure that you can get the most from your SF S. The procedures for scanning consecutive slides with the SF S may be found in the software reference manuals provided on the CD-ROM that came with your scanner.